Frequency Measuring:
-Single Port Swept Frequency Measurements of Antennae Operating in the 0.1-120 MHZ Frequency Range, (LF, MF, HF and FM Bands Included).
-Set the Frequency Range of Measurement By Specifying Beginning and Ending Frequencies.
Impedance Measuring:
-Measure Impedance and SWR at the Input Connector or Translated to the End of a Coaxial Cable with a Pre-Specified Characteristic Impedance.
-Use as an Impedance Bridge /Receiver-Generator Utilizing an Internal Tone Generator to Adjust to a Pre-Specified Reactance or Impedance.
-Use to Measure the Impedance of an AM Radiator With Up to 50 Volts Peak To Peak RF Incident on the Tower on the Same Frequency. The Analyzer is Self Protected for an RF Overload Maximum Voltage of 100 Volts Peak to Peak.
More Features:
-Calibration Procedures Similar to that of a Network Analyzer Utilizing Open, Short and 50 Ohm Loads that are Supplied with the POWER AIM 120 Analyzer.
-Use to Measure the Electrical Length of a Transmission or Sample Line.
-Save Time -Use to Locate a Fault in the Transmission Line
-Display Data in a Linear Format or on One or More Smith Charts
-Organize Data Files by Saving, Printing or Importing into Spreadsheets
|