| RFC-200-80-1S-L | R.F. Motorized Switch, Single Pole Single Throw 200A/80KV W/ ACSP AND 24 VDC REGULATED POWER SUPPLY (50/60 Hz 100 – 240 VAC at 1.6 Amp Max.)
|
|
| RFC-200-80-1-L | R.F. Motorized Switch, Single Pole Double Throw 200A/80KV W/ ACSP AND 24 VDC REGULATED POWER SUPPLY (50/60 Hz 100 – 240 VAC at 1.6 Amp Max.)
|
|
| RFC-150-55-1S-L | R.F. Contactor, 150 A, 55 KV, SPST (220 VAC) W/ ACSP AND 24 VDC REGULATED POWER SUPPLY (50/60 Hz 100 – 240 VAC at 1.6 Amp Max.) |
|
| RFC-150-55-1-L | R.F. Contactor, 150 A, 55 KV, DPST (220 VAC) W/ ACSP AND 24 VDC REGULATED POWER SUPPLY (50/60 Hz 100 – 240 VAC at 1.6 Amp Max.) |
|
| RFC-200-30-1-L | R.F. Contactor, 200 A, 30 KV, SPDT (220 VAC) W/ ACSP AND 24 VDC REGULATED POWER SUPPLY (50/60 Hz 100 – 240 VAC at 1.6 Amp Max.) |
|
| RFC-200-30-2-L | R.F. Contactor, 200 A, 30 KV, DPDT (220 VAC) W/ ACSP AND 24 VDC REGULATED POWER SUPPLY (50/60 Hz 100 – 240 VAC at 1.6 Amp Max.) |
|
| KTL-WAC-PLC-24VDC | WEB ACCESSIBLE DIRECTIONAL AM SYSTEM CONTROLLER (CONTACT US FOR CUSTOM PRICING)
|
|
| AS-PA120 | Power AIM 120 portable Vector Impedance Analyzer for commercial broadcast |
|
| AS-PA-120-15 | Power AIM 120 portable Vector Impedance Analyzer for commercial broadcast w/ 15" Laptop/Case |
|
| AS-PA-120-17 | Power AIM 120 portable Vector Impedance Analyzer for commercial broadcast w/ 17" Laptop/Case |
|
| VNA2180 | The VNA 2180 measures impedance (magnitude and phase) and filter transmission in the range of 5KHz to 180 MHz.
A PC is used to plot parameters, such as, impedance, SWR, S11 and S21.
The test frequency is generated digitally. A 12 bit analog to digital converter digitizes the raw data. This avoids non-linearity associated with diode detectors, and results in very good dynamic range and linearity for accurate magnitude and phase measurements.
Main Features
• Port A is equivalent to an antenna analyzer. (Similar to the AIM4170C)
• Port B has a 50 ohm input impedance with return loss greater than 30dB
• Port B dynamic range: 100dB up to 50MHz, 80dB up to 160MHz
• Programmable RF amplitude for Port A (+7 to –19 dBm).
• Resistance and reactance measurements of antennas and discrete components
• Impedance measurements through filters or networks
• Markers for impedance scans and Smith charts
• Parameters that can be plotted include:
o Resistance and reactance for series or parallel equivalent circuits
o SWR or reflection coefficient (S11)
o Return loss
o Phase angle with sign
o Two port network transmission (S21)
• Cable length, impedance, loss, and velocity factor
• Distance to fault (open or short)
• Smith chart displays (featuring phase rotation and zoom)
• Band scan to check for interfering signals
• Quartz crystal parameter measurements
• Preprogrammed functions, such as tuning a ¼ WL stub, and many more
• Calibration loads are included
• No internal adjustments
• Optically isolated USB interface to PC
Impedance measurements can range up to 10K ohms. The sign of the phase angle indicates either inductive or capacitive reactance without ambiguity.
The RF generator can also be used as a signal source for testing receivers. The frequency is very stable and it can be calibrated to WWV.
Digitized data is sent to the PC via an optically isolated USB port. Power for the VNA can be obtained from a small DC power supply or a battery. With a laptop computer, the unit is quite small and portable. Measurements can be made at ground level and translated as if they were at the antenna feedpoint by using the refer to antenna function.
The impedance at the antenna itself can be read with the VNA located in the shack at the receiving/transmitting end of the coax. The cable can be any length. The cable's impedance and loss characteristics are determined by a simple calibration procedure and the antenna's impedance is then plotted directly during the scan.
Numeric values can be read from the graph data using the mouse-controlled cursor.
The scan data can be saved to disk or printed to compare before and after results. It can also be imported into spreadsheet programs for further analysis.
|
|